Gf-signet 2552 Field Wireable Connector User Manual

Browse online or download User Manual for Tools Gf-signet 2552 Field Wireable Connector. GF Signet 2552 Field Wireable Connector User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Signet 2552 Field Wireable Connector
When properly tightened, there will be
approximately a 2 mm (0.08 in) gap
between the two end rings.
Plug Connection
The plugs are joined by holding the main body on each connector and gently
mating them together while lining up the alignment tab and notch on each.
With inward pressure, grasp the rings at the ends of the plugs (silver on male,
large black on female) and twist in opposite directions to engage the threads and
tighten. Engagement should be smooth.
Signet 2552 Field Wireable Connector
*3-2552.397.398.090*
3-2552.093 Rev. A 06/10 English
English
Cable Connector Accessory for 2552 Metal Magmeter
Installing Cable to Connector
Wiring
Tips to remember when making your own cable:
1. Maximum total cable length = 300 meters (1000 ft).
2 Keep the number of cable connectors to a minimum.
3 Use 22–18 AWG (5–6 mm) four conductor cable with shield for best signal transmission.
4 Make sure the cable connector is assembled properly.
7 mm
20 mm
10 mm
Bare Shield
Strip off 20 mm (0.78 in.) of outer cable jacket.1.
Strip off 7 mm (0.27 in.) of insulation from the end of each of the four colored wires.2.
Cut off 10 mm (0.39 in.) from bare shield wire.3.
Unscrew connector from body. Use a small screwdriver to connect the wires.
If using non Signet wire, Pin Number = Wire Number Assignment.
3-2552-XX-A-XX
Requires 1 male
+ 1 female plug to extend
the cable of the "A" version
Female connector
Female
(Back of plug)
4
1
3
5
2
Male connector
Male
(Back of plug)
1
4
2
5
3
Female
(Back of plug)
3-2552-XX-B-XX
(Requires 1 female plug)
Male
(Front of plug)
1
2
3
5
4
Alignment Tab
Female
(Front of plug)
1
2
3
5
4
Alignment Notch
Female connector
Pin Number or
Wire Number Assignment
4
1
3
5
2
1 Brown
2 White
3 Blue
4 Black
5 Bare Shield
Pin Number
(on connector)
Signet Wire Color
Page view 0
1 2

Summary of Contents

Page 1 - *3-2552.397.398.090*

Signet 2552 Field Wireable ConnectorWhen properly tightened, there will be approximately a 2 mm (0.08 in) gap between the two end rings.Plug Connectio

Page 2 - Non-Signet Instrument

3-8900.621CI/O Module 3-8900.401-X1234567891011121314+5VDC (Black)Freq. Input (Red)GND (Shield)+5VDC (Black)Freq. Input 2 (Red)S L (Red)GND (White/S

Comments to this Manuals

No comments